Description:
1. sphygmomanometer for pet2. doppler ultrasound vet sphygmomanometer
3. probe 8MHZ
4. vet instrument manufacturer
portable dopplerultrasound sphygmomanometer for pet fromchina
Sphygmomanometerfor pet
1. dopplerultrasound sphymomanometer
2.sphymomanometer is special for pets
3. probe: 8MHZ
4. five size cuff is for thedifferent age pets
5.R&D veterinary instrument manufacturer
Product Specification:
1. Measuringrange:0mGs~199.9mGs
2. Frequency of the probe: 8MHz
3. Specification of the blood pressure cuff
Range: No.1 4.2cm~7.1cm
No.2 5.4cm~9.1cm
No.36.9cm~11.7cm
No.4 9cm~13cm
No.5 12cm~16cm
(17cm~22cm , ( No.6 :17cm~22cm optical additional charge$15)
4. Rechargeable battery voltage:7.4V , 1500mAh)
5. AC input: 100~240V 50/60Hz DC output DC8.4V, 1000mA
6.Continuous working time :> 8 hours
7.Speaker: 4Ω, 1W
8.Gross Weight: 3.86kg
9.Package size: 45*35*23cm
We''re aleading R&D vet instrument manufacturer in theworld.
Wecome to visit ourwebsite: www.goldenbrains.com
Components&Productsize
| pet sphygmomanometercompenents | 1.a power switch /volume control:turn on the instrument and adjust the volume. 2.the power indicator: Indicatespower connected or not connected. 3.headphone jack:mainly used to connect headphones. |
| petsphygmomanometer Size | Host: 192mm (L) x 84mm (W) x 30mm (H) Probe: 20mm (D) × 120mm (L) Weight: about 300 grams (including battery and probe) Outer packing: 37cm (L) x 31cm (W) x 14cm (H) |
| petsphygmomanometer Package | aluminum box: 45*35*23cm |
( Note: The fivedifferents specifications of the cuff is suitable for differentsmall animals. )
The Doppler host operatinginstructions:
1.the probe cable toconnect to the probe interface, turn the power switch, theequipment to begin testing.
2.to ensure that the power indicator is lit, turn the volumecontrol rotation to a minimum, and then increase the volumeslowly.
3. smear the ultrasound gel on the skin of the probe at the top andthe measurement region.
4.the probe is placed in the measurement area, and then movedslowly to find the highest value of the Doppler soundintensity.
5.in the case of headphones are connected, automatically turn offthe loudspeaker, and help us to better listen to the Dopplertone.
6.the power light does not shine, you need to recharge thebattery.
operation:
1. inflatable steps: in the case of thedeflation valve closed, pinch the inflatable capsule softly, to thecuff inflated.
2. deflated steps: in accordance with the direction of the arrow,gently touch and press to release the gas switch, slowly open thedeflate valve, until the cuff gas discharged; loose open airswitch, put the gas valve closes automatically, can bere-inflated.
In end of deflation, continue alittle harder to press the switch, the valve is fully open, removeyour finger, the valve does not close automatically, this statewill not be able to cuff inflation; need direction of the arrow alittle harder to the touch pressure above the deflation switch inorder to close the valve, the next inflation.
3,the cuff connection steps:
Clinicalapplication skills:
1, It is recommended not tape thesensor fixed at a certain position, because of the foot or legslightly move will cause the sensor to shake, making the arterialsound disappears; with your thumb, press and hold the sensor, ifthe arterial sound disappears slowly move the thumb re-positioning,than open the tape again fixed in order to save time. 2, Inorder to make the sensor contact with the skin as possible, youneed to apply some pressure, but not too much pressure, becausethis may cause the artery to stop the flow.
3, It is recommended that the inspection process using headphones,and can more easily hear the Doppler tone, while preventloudspeaker harsh sound to scare the cat to be tested; In addition,the use of headphones to check, you can also reduce the surgicalprocedure to sick animals caused by pressure.
4, If the use of loudspeakers, the volume adjusted to make the earsfeel more comfortable on the contrary, the volume is too small willlead to miss some voice to listen to the process.
5, To the appropriate leg extension commence, because the arterialblood flow measurements of bending the legs of sick animals, willbe unusual restrictions, resulting in low readings or errorreading.
6, Generally require seven measurements, remove the highest andlowest values to calculate the other five times the average ofmeasurements, this is called the systolic blood pressure values,measurement units of mm Hg; some tense cat microphone in theinspection process slowly relax down several times during testing,the first few values may be very high, behind will be low. Weusually will be in front of several numerical ignored behindseveral times as the correct value.
Note:
A probe is used in skin, we shouldturn off the power switch in time after using; probe is very thinand fragile, so be sure to pay attention not to damage the top ofthe probe (and is also very expensive to replace them) ;
if collided with sharp objects,it is broken easily, so be careful. Ultrasonic coupling agentis usually in the testing process with the ultrasonic couplingagent, can not use ECG gel or baby oil, because these substanceswill corrode the sensor surface, as not only can not generate thecorrect Doppler tone, and it will damage the probe. When thebattery power is low, the power light began to fade, and similarly,the amplifier will stop the voice, this time to recharge thebattery.
Cleaning:
1. To clean up the ultrasound gelabove the probe after used, use cotton balls dipped inalcohol wipe. Before the use of disinfectants or fungicides,we should ask the producer whether it isappropriate.
2. in the process of cleaningbody, we need to prevent the body from water.