Office Supplies
Skin Closure Stapling Device
2016-12-18 23:32  Views:293
Price:Negotiable
Send Inquiry

Description:

1. Sterilized Devices with stainless steel inner nail
2. We give the skin stapler remover as presents
3. Skin stapling

35wSkin Closure Stapling Device  Made inChina

 

 

Skin Stapling ApplicableOperation: 

1.Applicable to trauma and the surface of the skin incisionsuture

2. Its usedin Operating Room. Labor and Delivery. Emergency Department.Outpatient Surgery. Clinics and Physician"s office.

 

Features &Benefits: 

1. TotalLength:120mm  Total Height: 60mm

2A.Upper handle and neath handle: ABS Engineering Plastics. 

   B.Staple press-board and staple slot board:12Cr18Ni9 stainless steel.

  C. Staple: 00Crl8Nil4Mo3. 

3.Certification: CE ISO

4.Surprise: If you buy 30 pcs  disposable skin stapler then wegive 3 pcs skin stapler remover as presents and soon......

 

 

 

 

 

Structure composing:

Disposable Skin Stapler is assembled by body frame and staples, the staple remover is the subassembly of skin stapler. The body frame is assembled by upper handle,neath handle,staple slot board,staple press board and fix frame.

 

Description of performance and operation:

Choose the appropriate number of staples and specifications according to the length of suture.Using the teeth forceps to clamp wound skin which have been debridement and disinfection,the Skin Stapler will be perpendicular to the wound, suture the skin wound by grip handle, release the handle smoothly(Attention not to pull the skin stapler at that time),pulling the stapler vertically,To complete the suture operation of one staple. It has the matching stapler remover to remove the staple easily when removed the staples.

 

Contraindications:

1 Patients with sensitive or allergic reactions please do not use this device.

2 It is not suitable for the incision which needs to do tension suture use After the operation 

3 If the distance of skin incision and the internal key tissue is not enough 5mm, prohibit using this equipment to suture the skin.

 

Warnings:

1 The product has been sterilized by gamma ray (cobalt 60) at delivery. The product can not be used anymore when packing is damaged. 

2 If the product is defective in visual check or is damaged in suspicion, the product shall not be used anymore. Please contact the representative of our company. 

3 The product is only for one-time use and shall not be reused. Repeated processing or repeated sterilization may damage the product, and cause injury, infection or death of the patient. If the product is reused, the product may be polluted, or the patient is infected, or cross infection occurs. 

4 The product is used only by the doctors who have professional knowledge on stapler and/or under the guidance of the experienced professional concerned. 

5 Do not operate this product before completely reading this operation manual. Any incautious operation may cause operation unsuccessful. 

6 After the product is used, it shall be destroyed. 

 

Precautions:

1Please check carefully the product packing before using. Do not use it if the packing is broken. 

2Please check the mark on the sterilized packing box of the product. "Yellow" mark means that this product is not sterilized and can not be used directly. “Red" mark means that this product has been sterilized and can be used directly in clinic. 

3This product is only for one-time use and can not be sterilized again after using. 

4Please check the valid period of the product before using. The valid period of sterilization is three years. The product can not be used after the valid period. 

5Sterilized product shall be stored in well-ventilated indoor without corrosive gases and with relative humidity not exceeding 80%. Prohibition of prolonged exposure to high temperature and avoid exposure to temperatures in excess of 54 °C environment.  

6Any stapler which has been dropped carelessly on ground or damaged actually or in suspicion shall not be used clinically. 

 

Skin StaplingPossible adverse reactions:

1 Likely result in infection; 

2 Likely result in tearing stoma; 

3 Likely result in bleeding at stoma.  

 

Sterilization:

This product is sterilized by gamma ray (cobalt 60) and can be used clinically. 

 

SkinStapling Ordering Information:

 

ModelNumber ofNailHeight ofNail(mm)
PYPF-35A354.5

  

 

 

Our othersurgical devices:

Contact Infomation
Send Inquiry
Company name:Chongqing Haijing Apparatus Co., Ltd.
Status:[Offline] [Send message] [Chat]
Business contact:unfilled(Mr.)
Telphone:
Area: Caribbean Region-Bermuda
Address:Room 13-7, No. 218, Chaotian Village, Shiqiaopu, Jiulongpo District