Office Supplies
RTD XKPD/MF5A Epoxy-Sealed series NTC thermistor(temperature instrument)
2016-12-14 01:12  Views:133
Price:Negotiable
Send Inquiry

Description:

RTD
Electric thermo meter, electric calendar, electric clocktemperature presentation and electric gifts.

RTD

(1) Appearance and Dimensions

  Unit:mm

Φ:0.2~0.6, specific dimensions may be made asrequired by customers.

(2)Features

• Epoxy enclosed, small in volume, with quickresponse time and high sensitivity.

• Stable in working, high in reliability andprecision.

 

• Consistent and easy to interchange.

(3)Purpose

• Precision temperature measurement.

• Temperature compensation for electric circuits.

• Temperature measurement and control circuit.

(4)Application

• Electric thermo meter, electric calendar, electric clocktemperature presentation and electric gifts.

• Cooling and heating equipment, electric heating constantappliances.

• Automobile electric temperature measurement and controlcircuit.

• Temperature sensor and temperature instrument.

• Medical electrical equipment and electric toiletfacilities.

(5)Description of Product Types andSpecifications

 1. KPD —— Abbreviations for KePengDa.

2. MF -—— Indicates negative temperature (NTC) coefficientthermistor.

3. 5A —— Temperature measurement type epoxy enclosedthermistor.

4. 103 —— Nominal resistance of thermistor, e.g. 103 indicatesthat the nominal resistance of the thermistor is 10 *103 (Ω).

5. G —— Resistance error (precision), e.g. G indicates the error(precision) of the thermistors is ± 2%.

6. 360 —— Material factor B25/50 value of thermistor,e.g.360 indicates the material factor B25/50 value ofthe thermistor is 360*10K.

7. F —— B25/50 error (precision), e.g. F indicatesthe B25/50 error (precision) of the thermistor is ±1%.

Note :R25 precision :F(±1%), G(±2%),H(±3%), J(±5%), K(±10%).
                  B25/50precision :F(±1%), G(±2%), H(±3%).    

 

(6)Main Technical Parameters

Parameters

Parameter range

Test conditions

R25(nominal resistance)

500 Ω~ 200K Ω

Constant temperature
25 °C± 0.05 °C

Allowed R25 deviation (%)

± 1 , ± 2 , ± 3 ,
± 5 , ± 10

Constant temperature
25 °C± 0.05 °C

B25/50(material coefficient)
(thermal sensitive index)

3000 ~ 5000K

Constant temperature
25 °C± 0.05 °C
Constant temperature  
50 °C± 0.05 °C

Allowed B25/50 deviation(%)

± 1 , ± 2 , ± 3

Constant temperature
25, °C± 0.05 °C
Constant temperature
50 °C± 0.05 °C

δ(dissipation factor)

≥ 0.7mw/ °C

In still air

τ(thermal time constant)

≤ 3.4S

In still air

TA(working temperature)

-40 °C ~ 125 °C

 

PN(rated power)

50 mw

In maximum working temperature

 

Contact Infomation
Send Inquiry
Company name:Shanghai Cixi Instrument Co., Ltd.
Status:[Offline] [Send message] [Chat]
Business contact:Agnes Peng(Mr.)
Telphone:
Area: Caribbean Region-Bermuda
Address:Rm613, Jiahe Sunny Plaza, No.76 JiuTing Road, Songjiang District, Shanghai, P.R. China.