Description:
1.identify day and night automatically 2.material:PC(UV proof)3.outdoor sensor with IP44
PIRMotion Sensor ST12 Ceiling Mount IP44 With TUV PCMaterial
Thisproduct is a new type of energy-saving lighting switch, it adoptshigh sensitivity detector, integrate circuit and SMT; It gathersautomatic, convenient, safe, energy-saving, practical functions; Ithas wide detection range made up of up and down, left and rightservice field; It utilizes human motion infrared rays as controlsignal sources, when one enters the detection field, it will startthe controlled load at once; It can identify day and nightautomatically; It is easy to install and its usage is wide; It hasthe function of power indication and detectionindication.
Electronicalcharacteristics
| Power Source | 110-130V/AC; 220V/AC-240V/AC | Detection Range | 180º |
| Power Frequency | 50/60Hz | Working Temperature | -20~ 40°C |
| Time-Delay | 10sec±3sec to 7min±2min | Ambient Light: | 3-2000LUX (adjustable) |
| Rated Load | 1200W (incandescent lamp) 300W (energy-savinglamp) | Installation Height | 1.8m~2.5m |
Detection Distance | 12m max(<24°C) | Power Consumption | 0.45W (work) 0.1W(static) |
Lifetimeand warranty
| Lifetime(hr) | 26000-45000at least |
| Warranty | 3 years |
FUNCTION:
- Detectionfield: The wide detection range is made up of up and down, left andright, the detection range could be adjusted according to yourdesire, but the moving orientation in detection field has greatrelation with the sensitivity.
- Identify dayand night automatically: The ambient light of ST12 could beadjusted according to your desire: when turn to SUN (max), it willwork day and night, when turn it to MOON (min), it will only workin the ambient light less than 3LUX. As for adjustment, pleaserefer to testing way.
- Time-delayis added continually: When it receives the second induction signalsafter the first induction, it will compute time once more on therest of the first time-delay basis (set time).
- Time-delayis adjustable: It can be set according to your desire, the minimumis 10sec±3sec, and the maximum is7min±2min.
INSTALLATION:(see thediagram)
- Shut offpower.
- Loosen thescrew on the bottom lid, open the wiring terminal, pass the wire ofpower and load through the bottom lid.
- Fix thebottom lid with inflated screw on the selectedposition.
- Connect thepower and load wire into connection-wire column according to theconnecting figure.
- Put thesensor on the bottom lid, twist the screw tightly then electrify itand test it.
CONNECT-WIREFIGURE:(See the right figure)
TEST:
Turn time knob anti-clockwiseto the minimum; turn the LUX knob clockwise to the maximum(SUN), Switch on power,the controlled load should not work, needing to preheatwithin5-30sec.
The sensorwill be sensed again in 5-10sec later when the first induction isfinished; the load should work when received sensor signal and stopworking within 7-13sec with no any sensor signal.
- Turn LUXknob to minimum anti-clockwise, if you test it when the ambientlight is more than 3LUX, the induction load would not work afterthe load stops working; the load should work if you cover thedetection window with opaque object (towel etc), it would beregular the load stops to work within 7-13sec under no inductionsignal condition.
our company adopts automatic machines, such as: SMD, auto component inserter, wave solder, auto injection machines, the daily output isup to 20000-30000 pcs.
Theconcept of our company is"advocating new modern livng environment",which focuses on reserching the and developing tocontemporary household intelligent product.our poduct can betrulysatisfied for different customer''s requiement, most of themare available with CE GS ROHS R&TTE REACHcertification.