Description:
Wireless GPRS Datalogger;Wireless GPRS Temperature Data Logger;
Wireless GPRS Fuel Level Data Logger;
GPRS Automation.
Specifications
Siemens MC55i quad-band GPRS Module
low cost, multi-function
transmit and receive data
1 RS232 Serial Port, and 1 RS485 Serial
GSM GPRS RTU TelemetryLogging Engine S240 Series , data logger
TheKing Pigeon S240 Serial GSM GPRS Telemetry Engine equipped SiemensMC55i quad-band GSM Module inside, is a low cost, M2M, data logger,universal GSM GPRS Engine which can transmit and receive analog,digital and pulse counter data, PLC, Varity metering equipments toany device connected to the GSM/GPRS network such as mobile phones,Web Sites, monitoring center, control room.
>>>ModelListTable:
Model | Analoginput | Digitalinput | Temp.input | Relayoutput | USB | RS232 | RS485 | SCADA | Battery |
S200 | 4 | 2 | 2 | 2 | 1 | / | 1 | Yes | Yes |
S220 | 6 | 6 | 2 | 4 | 1 | / | 1 | Yes | Yes |
S240 | 10 | 6 | 2 | 4 | 1 | 1 | 1 | Yes | Yes |
>>>S200,S220, S240 GPRS Data Logger Features:
>Direct connection tothe GSM GPRS Network;
> Transparent Serial DataTunneling using low cost SMS/GPRS network;
> Remote Configuration by SMSMessages or GPRS;
> Upload data via GPRS or SMS onSchedule or event occurs;
> Supports Dynamic Domain name orfixed IP address;
> Supports SMS, CSD, GPRS, UDP andTCP/IP protocols;
> Supports Modbus RTUprotocols;
> 2 RS232 Serial Ports, and 1RS485 Serial Ports;
> UP TO 6 OPT Coupler (5-24V) DigitalInputs can be programmed to NC/NO/Edge/Level typeby switch, OPT and NON OPT can be programmed by switch, when alarmoccurs can send Alarm Messages by SMS or GPRS or auto dial thepreset phone numbers;
> UP TO 6 digital inputscan be used as PulseCounters;
> UP TO 4 OPT Digital Outputscan be programmed as dial to switch on/off with free communicationfee, alarm-linkage and Schedule to action, also can be send SMS toswitch on/off;
> UP TO 10 Analogue Inputs. (12bit resolution, 0-5V or 4-20mA can be programmer byswitches);
>UP TO 4 Digital Relay Outputs:120VAC/3A, 24VDC /3A, Can be controlled by Event,scheme, Incoming call, SMS Commands, Timer, Interlock; 2 outputscan setup as NC or NO type;
> User friendly PC ProgrammingInterface, it can remotely program the terminals as well as to upload the data from the terminals by SMS or GPRS, all of theCurrent Value or status of the terminal can be display directly,and also will display the SMS Command details while you programmingit;
>>>>>>>GPRSData Logger S200, S220, S240 is a Low cost Remote GPRS MonitoringSuitable for:
>Environmental
>Pumping station
>Gas dataacquisition
>Oilfield
>Power Station
>Rain gauge
>Urban water supply pipenetwork
>Reservoir
>Meter readingsystem
>Sewage treatment
>Transformer
>Water level
>>>>>Specifications of GPRS RTUS240:
Parameter Item | Reference Scope |
DC Power supply | Standard adapter: DC 12V/1.5A Reference scope 9-24V DC |
Power consumption | Standby:12V/70mA; Working Max.: 12V/300mA |
GPRS Module | Siemens MC55i |
Frequency bands | Quad-band: EGSM 850, EGSM900, GSM 1800, GSM 1900, Compliant to GSMPhase 2/2 |
Transmit power | Class 4 (2W) at EGSM 900 and EGSM 850; Class 1 (1W) at GSM 1800 andGSM 1900 |
GPRS connectivity | GPRS multi-slot class 10 |
GPRS Data Transmission | GPRS data downlink transfer: max. 85.6 kbps; GPRS data uplinktransfer: max. 42.8 kbps. |
TCP/IP stack | TCP, UDP |
SIM interface | Supporting 3V SIM Card |
External antenna | Connected via 50 Ohm antenna connector or antenna pad, SMA Antennainterface |
Serial Interfaces | 1 RS-232 Port, 1 RS485 Port, 1 USB Port; |
Protocols | SMS, GPRS UDP, TCP, Modbus RTU, and more equipment protocols can beadded according to requirements. |
Digital Inputs | 6 OPT Coupler (Active Contact 3-24V);NC/NO/Edge/Level type; ActiveContact and Passive Contact By Switch; Can be used as PulseCounters; |
Analog Inputs | 10 Analog Inputs. 12 bit resolution, 0-5V or 0-20mA; |
Thermometer Inputs | 2 Ports DS18B20, Measures temperatures from -55°C to 125°C.Fahrenheit equivalent is -67°F to 257°F, ±0.5°C accuracy from -10°Cto 85°C, Thermometer resolution is 12 bits. |
Digital Relay Outputs | 4, 120VAC/3A, 24VDC 3A, Can be controlled by Event, scheme,Incoming call, SMS Commands, Timer, Interlock; 2 outputs can setupas NC or NO type; |
Power Source Outputs | 3 Ports with 3.3VDC/400mA Power for external device; 1 Port with12VDC/750mA Power for external device; |
Internal Backup Battery | 7.2v 1200mAH |
Work Temperature range | -10- 70 °C |
Humidity range | Relative humidity 95% (condensation free) |
Exterior dimension | 168mm*113mm*32.3mm |
Net Weight | 1000 g |
>>>>StandardPackagelist:
>>GSM/GPRS RTUx1
>>Power supply adapter x1(12V 1.5A 1)
>>USB cable forcommunication x1
>>CD disk (PC Configuratorand User Manual) x1
>>GSM Antenna x1
>>PackageSize:W300*D205*H75MM
>>Gross Weight:1.5KG, 5Pcsper carton
>>>>>>>Why KINGPIGEON?
KingPigeon is a professional GSM Wireless Alarm, GSM Home AlarmSystem, GSM SMS Alarm, GSM SMS Controller, GSM Home Automationsystem, Industrial Remote Controller, GPRS RTU Data Logger, GSMTelemetry, Temperature Measurement Logger, Power Monitoring Alarm,GSM M2M Products Manufacturer since2005.
based onmore than 7 years rich experiences, King Pigeon provideProfessional High Quality and Reliable OEM/ODM service for themarket in worldwide!
Welcome OEM/ODM Service
Put Your LOGO on Unit and Package Available!
Your anyrequests would be much appreciated, please do not hesitate tocontact us.
Skype: gsmhousealarm