1.Always keep the battery on the full state
2.Overcharge protection.
3.Transform AC to DC.
The battery charger JUTA CBP-12V/10A cantransform the electrical energy of 230Valternating current into 12V direct current for the fast batterycharging.
JUTA charger takes the most advanced electronic circuit,the thermal is much less than the general commutate circuit, andalso the conversion efficiency is much higher than others.
JUTA battery charger takes the adjust technology of PWM,float charging the batteries which get to the fit voltage. It keepsthe battery in full charge state. There is no worry about thebattery damaged for overcharging even long time charging.
Chargeoperation:
1. Turn the switch on-off of power to the OFF
2. Take the RED clip on the positive pole stable, and take theBLACK clip on negative pole - stable.(must be correctlyconnection)
3. Insert the AC plug of the charger into the electrical outletof 220V AC electrical source.
4. Turn the switch on-off of power to the ON, the charge isstarted.
Indication:
1. One piece of green charge indicator (CHARGE) light. Indicatecharge state: When the CHARGE bright, that means the battery ischarged strongly, flickeringly means floating charge, no lightmeans charge stopped.
2. One piece of RED protection indicator (PROTECTION) light,Indicate the malfunction: When the PROTECTION is bright, that meansthe fuse destroyed, we need to change the fuse.
3. In the respect of two types of CBP-06/10 three pieces of redbattery indicator (BATTERY LEVEL) lights, indicate the voltageheight of the battery. In the respect of CBP-20 one piece ofvoltage meter indicate the voltage height of battery.
4. One piece of ampere meter, used for indicates thecurrent.
Stop charge:
When the CHARGE start flickering, that means the chargebasically finished. We can stop charge; But it is better to chargethe battery continual 3 hours more, so that the battery will bemuch full.
The sequence of stop charge: Turn off the power switch, lift theAC electrical energy plug, then move the slip which on thebattery.
Function of Protection:
JUTA battery charger has Short Circuit ProtectionOverloadProtection Reverse Connection Protection. When the protectionworked, the fuse will destroy itself, at the same time the chargestopped. PROTECTION indicator light gets light.
2. If you want to change the safety pipe, please make sure theAC plug has been cut and the slip of the battery has beenmoved.
Attention Items:
1. Before connection, please check and confirm the rated voltageof the batteries. The rated power of the battery must be 12V, or itwill destroy the charger.
2. Although there are so many protections on the batterycharger, we have to avoid short circuitoverloadand reverseconnection happened.
3. The fuse must be changed by same rated current one, and itcan not be increased discretionarily.
Technical data:
Model | CBP-06A/12V | CBP-10A/12V | CBP-20A/12V |
Rated Voltage of the Battery | 12V | ||
Fit capacity of battery | ≤60Ah | ≤100Ah | ≤200Ah |
Input Voltage | AC 195245V | ||
Input Power | ≤80W | ≤135W | ≤270W |
Voltage of Charge | DC1014.5V | ||
Current of Charge | 6A | 10A | 20A |
Efficiency | 85% | ||