Brand:enwint
EP12/24 10H-1-2L adopts MCU and special software achieving,intelligent control with five operating modes, featuring smallvolume and high stability. This product can be widely used in solarDC road lamp, solar yard lamp, lawn lamp, solar lightbox andbillbord etc.
Performance:
1. 12/24V automatic identification.
2. Extreme accuracy in controlling voltage. Adopting 32-bitprocessor.
3. Automatic temperature compensation function. Hot-awappable toaid temperature transducer.
4. PWM charging modes with higher efficiency.
5. All-round protection function against overcharging,overdischarging, wrong connection, opencircuit, controller andbatteries in over temperture, overvoltage, overload, shortcircuit,reverse charging in night etc.
6. Applying nixie tube work modes in overvoltage and overloadinstruction. A key operation for convinience and intuition.
7. Intelligent 3-section charging control, to assure batteries offullness, system will switch to relvant modes according to thewoking status.
8. Adopting low-loss, long-life MOSFET tube as main switchingdevices in controller.
9. Auto-saving function for working mode setting. System andimportant parameters saved inner chip without losing power.Relevant parameters would be read while booting.System is morereliable to work.
10. Various operating modes for choice, optic control, opticcontrol time control, common mode, manual mode and advancedmode.
Data Sheet:
Model | EP12/24 10H-1-2L |
Rated voltage(V) | 12V/24V AUTO |
Rated charging current(A) | 10 |
Rated load current(A) | 5(single) |
Rated efficiency(W) | 120???×2/24V |
No-load loss(mA) | ≤20 |
Charging circuit voltage drop(V) | ≤0.2V |
Discharging circuit voltage drop(V) | ≤0.1V |
Forcing charging voltage(V) | 14.6???×2/24V |
Equalizing charging voltage(V) | 14.2???×2/24V |
Floating charging voltage(V) | 13.7???×2/24V |
Overvoltage protection voltage(V) | 17???×2/24V |
Overvoltage return voltage(V) | 15???×2/24V |
Undervoltage protection voltage(V) | 10.8???×2/24V |
Undervoltage return voltage(V) | 12.3, ×2/24V |
Enviromental over-temperature protection | Over 75??? over-temperture protection act, restartcharging at 65??? |
Batteries over-temperature protection | Over 75??? over-temperture protection start, restartcharging at 65??? |
Over load/short circuit protection | Over load protection will start after 60s or 20s of 1.25or1.5 times the rated current; and at above 2 times protection willcut off load |
Lines loss compensation voltage(V) | 0.2 |
Temperature compensation | -3mV/???/2V |
Control model | PWM charging model |
Working temperature | -20???~ 50??? |
Dimensions(L×W×H)(mm) | 154×88×25 |
Working elevation(m) | ≤5000(if altitude exceeds 1000m, ratings of operationshall be lowered according to standard GB/3859.2) |
Protection degree | IP30 |