1)spiral hose
2)co-extrusion forming
3)3-9 sub pipe
4)we make machine and pipe all
Ccorrugated optical duct COD.O.D CorrugatedOptic Duct It uses friction coefficient extremely lowmodified HDPE is the primary data, in the structure take thefriction coefficient extremely low long wall tube as the sub-tube,bears the high pressure, the easy curving corrugated pipe is thefemale tube, after compound squeezes out becomes. It bears the highpressure, but is curving, has the discrimination, the easyconstruction is the main feature, in the physical property, theservice life, aspects and so on project construction has thesuperiority
Optiroad C.O.D. opens new era of telecommunication backbone withits built-in multiple inner ducts (3 to 5) inside of the outer ductby means of assembling cable ducts in the course of production.Both inner and outer ducts are made of HDPE (High DensityPolyethylene) having high flexibility enabling rolled-on spoolregardless of numbers of inner ducts built-in.
.
Coiling Length of C.O.D.each reel may practically coiled up to 500meters, however, coiling even 1,000 meters of small dimension modelis also available. .
flexible and lengthy product of COD, it enables quick installationreducing considerable consecutive work quantities such as trenchexcavation, inner duct insertion
Description | Outer Duct(mm) | Sub Duct(mm) | |||||||
sub duct I.D(mm) X Nou. | O.D | THCK | I.D | O.D | THCK | I.D | Nou. | ||
28X5 | 110 | 10 | 90 | 33 | 2.5 | 28 | 5 | ||
32X4 | 110 | 10 | 90 | 38 | 3 | 32 | 4 | ||
36X3 | 110 | 10 | 90 | 42 | 3 | 36 | 3 | ||
36X4 | 120 | 10 | 100 | 42 | 3 | 36 | 4 | ||
50X3 | 160 | 17.5 | 125 | 59 | 4 | 50 | 3 | ||
Tolerance allowed | ±mm |
| |||||||
Outer Duce Outer Dia | 3 |
| |||||||
Outer Duce Inner Dia | 2 |
| |||||||
Outer Duce Thickness | 1 |
| |||||||
| 2 |
| |||||||
| 2 |
| |||||||
| 1 |
| |||||||
/
Test item | Technical Requirement | Test Result | ||
test data | conclusion | |||
1. Outshape | inner/outer wall smooth, color evenly, no bubble,no cracks, no impurity,no decomposition line | pass | grade | |
2. Structure and sise | outer duct O.D 115±2 | 114 | grade | |
sub duct I.D 32±2 | 31.9 | grade | ||
sub duct thickness 2.5±2 | 1.8 | grade | ||
outer duct thickness 1.5±3 | 2.6 | grade | ||
3.KN/m2 | whole duct |
| 39.1 | grade |
outer duct | ≥6.3 | 18.7 | grade | |
4.Press | give press to whole duct from vertical till shapechange to 40% of orignal shape and relax , non broken | pass | grade | |
5. strech strenth(inner) | ≥34.6MPa | 34.6 | grade | |
6.impact hammer test | temp 0°C,height 1m, 1kg hammper impact 10 times,above 9 times no broken | pass | grade | |
7.low tem. Fall down | low temp.-30°C, height 1m, fall down free, nobroken | pass | grade | |
8.inner side friction | ≤0.5 | 0.198 | grade | |
9.length shrinkable % | ≤3 | 1.7 | grade | |
/,