Brand:RL
MOQ:20
Quantity:4
130W CO2 Laser Power Supply
1. Product Features:
1. This laser power supply adopts zero current and half bridgesoft switch circuit, it makes the power supply have high efficiencyand quick response speed. Thus it is easy to match with CO2 lasertube made by any factories.
2. This laser power supply is easy to be controlled, it issuitable to High or Low level signal. The TTL level can controlstart or stop of laser output. While the power supply has emergencyprotection switch which can indicate water through andventilation.
3. The laser output power can be adjusted by 0-5V analog signal orPWM signal.
4. This laser power supply has open circuit protection function.When protective earthing is good, the laser power supply can be inopen circuit status during short time. This function canprotecpower supply when laser tube burst.
2. Aging test:
Each laser power supply must pass this test which is taken at 60degree centigrade for 12 hours in full load status. And the powersupply must start and stop at each 7 seconds for 500 times. In thisway we can ensure the laser power supply is qualified.
3. Specification:
Input AC Voltage | AC220V or AC110V | |
Input DC Voltage | DC 300V or DC150V | |
Input AC Frequency | 47-440Hz | |
Max. Output Voltage | 50KV | |
Max. Output Current | 30mA(Depends on Laser tube) | |
Efficiency | 91% | |
Over Current Protection | 130% of Max. Current | |
Open circuit Protection | Yes (For short time) | |
Cooling | Fan Cooling | |
Voltage Range of High Level Control | Not Less Than3V | |
Voltage Range of Low Level Control | Not More Than0.8V | |
Working Temperature | -30 - 65 Degree Centigrade | |
Humidity | 20-85%RH(No Dew) | |
Withstand Voltage | Input-Output | AC1500V/MinNot More Than10mA |
Input-Shell | AC1500V/MinNot More Than10mA | |
Output-Shell | Connected | |
Insulation | Not Less Than 50MOHM???DC500V??? | |
Leakage Current | Not Less Than 1mA???AC220V???Not More Than 0.5mA???AC110V??? | |
Shock Resistance | Amplitude: 0.5mm, Frequecy:10-55Hz, 3D Dretion:2 Hours | |
MTBF | Not Less Than30,000hours | |
Full Load 60 Degree Centigrade test | 12Hours | |
7 Seconds Start/Stop Test | 500 Times | |
Dimension???LXWXH??? | 328mmx222mmx80mm | |