Unique amortization system to eliminate contact bounce
Low cost
Accessories modification quickly and easily without usingtools
Various kinds of terminals for customers'' specialrequirements
Easy to change the coil
General amounting size, easy for replacement
Can be combined with a thermal overload relay to form anelectromagnet starter to protect the line in which overloadoperation may occur
Double E magnet assembly providing optimal performance withreduced power consumption
Effective dustproof cover available
Silver Cadmium Oxide contacts provide long electricalendurance.
Class F high temperature insulated coils are standard.

Technology Data

NUMBER
OF
POLES
COIL
VOLTAGE
50/60HZ
FULL
LOAD
AMPS
LINE VOLTAGELOCKED ROTOR AMPSRESISTIVE SMPS RATINGMAXIMUM HORSEPOWERBOX QUANTITYAPPROX UNIT WEIGHT
VOLTAGESINGLE
PHASE
THREE
PHASE
20FLA-3POLE
324
110/120
280/240
277
20240/277
480
600
120
100
80
30
30
30

110/120
200/240
480/600

1.5
3
-
-
7.5
7.5
25.45 kg
25FLA-3POLE
324
110/120
280/240
277
25240/277
480
600
150
125
100
35
35
35

110/120
200/208
240/277
480
600

2
-
5
-
-
-
7.5
10
25 br>20
25.45 kg
30FLA-3POLE
324
24
110/120
110/120
208/240
208/240
277
30240/277
480
600
180
150
120
40
40
40

110/120
200/208
240/277
480
600

2
-
5
-
-
-
10
10
15
20
25.45 kg
40FLA-3POLE
324
24
110/120
110/120
208/240
208/240
277
40240/277
480
600
240
200
160
50
50
50

110/120
200/208
240/277
480
600

3
-
7.5
-
-
-
10
10
20
25
25.45 kg

 

OTHER SPECIFCATIONS
20-30 FLA40 FLA
Line and Load Terminals#10-32 screw*Box Lug
Wire Size Awg Min-Max16-8**14-4 Cu/AL
Tightening Torque(Recommended)22 in ibs40 in ibs
Quick Connects:power Terminals Coil TermainalsDual 250 QC
Dual 250 qc(2)***
Dual 250 QC
Dual 250 qc(2)***
CoversOptionalStandard
Insulation System130 Class B130 Class B
*Stranding must be split for #8 wirt. **(1)#6-32screw and (1).250QC are optional.***Permissible AmbientTemperature: -40/65 -40F/150F

 

  COIL TECHNICAL DATA 50/60hzHLC Series
  Nominal Coil Voltage24120208/240277480
  Maximum Pickup Volts1888177220384
  Drop-Out Volts Range6-1520-7040-14065-185150-270
  Nominal Inrush VA@50Hz6565656565
  Nominal Inrush VA@60Hz6060606060
  Nominal Sealed VA@50Hz7.57.57.57.57.5
  Nominal Sealed VA@60Hz66666
  Nominal DC Resistance-Ohms6.61656608801320
Contact Infomation