Adopt DSP digital controltechnology
Adopt advanced DSP digital control technology, it improvesperformance and system reliability effectively, and achieveshigher
level of power density and miniaturization.Besides that, it canmeet all customers individualized needs, XPC11 series provide manyfunctions and users can configure the function according theirneeds.
Wide input voltagerange
With wide range of input voltage and frequency, ups can supplypower even in remote villages and poor power environment. Itreduced the frequency of battery discharge so that the battery lifecan be prolonged.
Perfect protection
The UPS contain I/P and O/P over protection, short voltageprotection, overload protection, short-circuit protection, inverteroverheat
protection, battery low voltage warning protection and batteryovercharge protection, etc. The aboves function make sure the
load works reliably and stably.The ups will turn to bypass whenoverload alarm.
User Friendly Display and Communication
The LED mimic diagram gives clear indication of real-time statusand power flow through the UPS.The large LCD graphical displayprovides an array of performance parameters, fault information andhistorical event log that are useful for troubleshooting.The systemprovides RS232 signals for remote monitoring, and SNMP (optional)for web-based monitoring.
Intelligent batterymanagement
Intelligent battery management technology extend the battery lifeand make the battery maintenance convieniently.The batteryself-testing technology can find battery problem timely.Withbattery voltage, overcharge protection to maximize the protectionof the battery is not damaged.
Abundant Optional
Friendly LED display (standard) or LCD display (optional).
Four kinds of optional cards provide network communicationfunctions (support dry contact, RS232, RS485 and TCP/IP
communication protocols).
| MODEL | XPC 1106 | XPC 1106L | XPC 1110 | XPC 1110L |
| Rated Power | 6KVA/4.8KW | 10KVA/8KW | ||
| INPUT | ||||
| Phase | L+N+G | |||
| Input Voltage | (120±5 to275±5)Vac | |||
| Input Frequency | (46±0.2 to54±0.2)Hz | |||
| Input PF | >0.99 | |||
| Bypass voltage | (187±5 to253±5)Vac | |||
| OUTPUT | ||||
| Output Voltage | 220Vac±1% | |||
| Output Power Factor | 0.8 | |||
| Output Frequency | Normal Mode, samewith utility power Battery mode: 49.9-50.1Hz | |||
| THD | THD<3% (linearload); THD<5% (Non-linear) | |||
| Transfer Time | Normal to batterymode: 0ms Bypass mode to normal mode : 0ms | |||
| Overload Capability | 105±5% 135±5% >150±5%: 0.1s to bypass; | |||
| BATTERY | ||||
| Voltage | 192Vdc | |||
| Charging voltage | 220Vdc | |||
| Overvoltage | 230Vdc | |||
| Charging Current | 2A/4A(Ltype) | |||
| SYSTEM | ||||
| Efficiency | >90% | >92% | ||
| Communication | RS-232 +Intelligent Slot | |||
| Restart Function | After Turning offdue to cut off voltage of battery, UPS will restart when voltage is in (175±5~285±5Vac) and frequency is in(47~53Hz). | |||
| Noise (1m front) | <45dBA | <50dBA | ||
| Operation Temperature | 0°C to 40°C | |||
| Humidity | 0~95%non-condensing | |||
| Storage Temperature | -40°C to50°C | |||
| Altitude | 1000m | |||
| Dimension(W*D*H mm) | 248x500x616 | 240x500x460 | 248x500x616 | 240x500x460 |
| Weight(kg) | 57 | 20 | 59 | 21 |
| Specification issubject to change without prior notice. | ||||