wet gas flow meter
2016-11-07 13:11  Views:270
Price:Negotiable
MOQ:1
Send Inquiry
  • Key Specification

    wet gas flow meter



    1.Main performances
     

    ModelXML-1XML-2
     XMF-1XMF-2
    Drum capacity(m3)0.002(2L)0.005(5L)
    Rated flow(m3/h)0.2(200L)0.5(500L)
    Top flow (m3)100100
    Excess flow(m3/h)0.3(300L)0.75(750L)
    Min. scale value(m3)0.8×10-50.2×10-4
    Normal pressure (Pa)10001000
    Accuracy in rated flow %/-1/-1
    Pressure in rated flow   Pa </=8080
    Outline dimensions(L/W/H)(mm)490×264×220490×264×304
    Net weight(Kg)4.55.4

    2.Measuring medium

    XML type is normal-type, it adopts brass material, and generallyused in the scope of
    non-corrosive gases.
    XMF type is anticorrosive-type, it adopts stainless steel material,can measure corrosive gases.

    3.Usage

    1. Put the meter on the worktable, adjust screws to enable blisterof leveler in the centre, and
    maintain for a long time in use.
    2. Open sealed screw cap of water level controller, pull outinternal wool rope.
    3. In the plug jack of thermometer or manometer, inject distilledwater into the meter, when
    redundant distilled water drain from hole of water level controller( sometimes it is clean when
    outflow one drop), then put wool rope in sealed screw cap of waterlevel controller, and fasten the
    sealed screw cap.
    4. Install thermometer and manometer, (every case 10Pa)
    5. Connect air channel according to direction of gas outlet andintake, and sealled.
    6. Open gas valve, and then you can measure gas.

    4.Attentions while using

    1. When you use it, you must always pay attention to the waterlevel in the meter, otherwise it
    will affect measuring accuracy.
    2. When you use it, temperature should be maintained at 15 ~ 25???, and the temperature is the
    same as room temperature, its temperature difference should be ≤ 2???.
    3. You’d better readout in a few weeks after the operation of themeter.
    4. When pressure of measuring gas is go beyond normal pressure 1 ~6 times (1 ~ 6 KPa), the
    meters can still work, at this time manometer should be removed ,then use rubber plug plugs up
    mounting holes of manometer.
    5. When flow of measuring gas is go beyond rated flow, the meterscan still work, but measuring
    accuracy will be greatly decreased.
    7. The meter should not be installed in a cold room, for fear thatit will freeze inside.
    8. In normal circumstances, check out accuracy every year atleast.

    5.Accessories

    1 pc of thermometer
    1 pc of manometer
    2 rubber plugs

    6. Diagram of the meter

     

    accuracy: /-1%

    accessory: thermometer,manometer,rubber plugs

    color: green or yellow

    model: corrosive type, normal type

  • AdditionalInformation
  • Payment TermsT/T,  Western Union,  Paypal, Others
    Minimum Order1pc
    Lead Time DeliveryTime7 days
    Sample AvailableNo
    FOB PortShanghai
    Loading Infousually by express
    Packing Infocarton
    Target Market(s)Africa,  Eastern Europe,  Hong Kong/Macao/ Taiwan,  Japan & Korea,  Latin America, Mainland China,  Middle East,  North America, Northern Europe,  Oceania,  South Asia,  SoutheastAsia,  Western Europe
Contact Infomation
Send Inquiry
Company name:Shanghai Cixi Instrument Co., Ltd.
Status:[Offline] [Send message] [Chat]
Business contact:Agnes Peng(Mr.)
Telphone:
Fax:
Area: Caribbean Region-Bermuda
Address:Rm613, Jiahe Sunny Plaza, No.76 JiuTing Road, Songjiang District, Shanghai, P.R. China.