Brand:VWG2008
MOQ:10
Quantity:10
Wind turbine charge controller''s specifications and technicaldate sheet.
1.Automatic voltage detection for 12 Volt or 24 Volt systems
2. Intelligent Microcontroller system is programmed to deliver bulkand float phase charging.
This feature ensures that batteries are optimally charged,
3. LED indicators keep the user informed about system workingstatus
4. The PWM electronic charge regulator tapers charge to the batteryby gradually limiting windcharger current to avoid batteryovercharge.
When regulating the turbine speed is graduallyreduced.
As fully charged batteries are more likely to occur in highwinds this slow mode of operation is safer and reduces wear
5.Temperature compensation automatically adjusts the settings ofthe regulator to take account of varying temperatures thus ensuringmaximum charging efficiency in all conditions.
| Model | VWG2008V2-12v/24v | |
| Rated power | 600W | |
| Max Wind Input Power | 500W | |
| Max PV Input Power | 100W | |
| Rated Battery Voltage | 12V | 24V |
| over voltage protective voltage | 17.5V | 32.5V |
| Battery over charge protective voltage | 14.32V | 28.64V |
| Battery over discharge protective voltage | 10.98V | 21.97V |
| Over discharge voltage recovery | 12.44V | 24.88V |
| Rated charge current | 40A | 20A |
| No load loss | ≤40mA | |
| Protection Type | 1,Over charged protection; 2.Over dischargedprotection. 3. Reverse polarity connection protection. 4. PVPanel reverse current protection. 5. Short circuitprotection. 6. Thunder and Lighting protection | |
| operation Ambient tempreture | -10~50oC | |
| operation Ambient humidity | 0~90% | |
| Size(W×H×D)mm | 228×133×75mm | |
| Weight KG | 1.2kg | |