Brand:HF-FYD
MOQ:100
Quantity:10
AC Input |
AC Input Voltage.............100~240V AC47~63 Hz
Inrush Current..............<30A(AC240V at 25°C)
input CurrentLimiting..............<2.5A(under min AC input and fullload)
Efficiency..............>80%
DC Output |
DC Voltage Regulation
Parameter | Line Regulation | load Regulation | Cross Regulation |
V1:12V | ±5.0% | ±5.0% | N/A |
DC Output Current
Parameter | Min Current | Rate Current | unit |
V1:12V | 0.1 | 1.0 | A |
Output Ripple &Noise............. 50 mVp-p@ 25 degrees C
Output Dynamic Load Response
Dynamic Load | DC Voltage Regulation |
50%~100%~50% | ±10% |
Overshoot at turn-on/turn-off.............<10%
ProtectionFunction |
SCP...........<0.1 ohms
OCPlimits.........6A
Timing |
Hold uptime...........>5mS(100Vac/47Hz),>10mS(110/220Vacc/50/60Hz)
Start uptime..........<3S(100Vac/47Hz),<2S(110/220Vac/50/60Hz)
EnvironmentRequirement |
Working temp...........0°C~ 40°C
Storage temp Range..........-10°C~85°C
Working humidity..........25%~90% relativehumidity (Non- condensing)
Storage humidityRange..........10%~90% relative humidity (Non-condensing)
MTBF............ 50K hours (25°C , Fullload and rated voltage input)
Product SafetyRequirement |
Standards............Meet IEC60950-1standardrequirement
Leakage Current.............not exceed 0.25mAat 220Vac/50Hz
Insulation Resistance...........≥50MΩ,500VDC
Dielectric StrengthTesting |
100%Hi-pot test
Item | Specification | Remark | |
Primary to Secondary | 1.5KVac | <5mA | No arcing No broken |
Primary to P.G | N/A | N/A | |
230V AC DC 12V 1A 1000mAswitching power adapter