Brand:YCF
MOQ:10
Quantity:100
Send Inquiry
| 1.SCOPE:12V8A 96W |
| The document is to specify thefunctional requirements of a 96W switching power supply. |
| 2.INPUT CHARACTERISTICS: |
| 2.1Input Voltage: |
| NominalVoltage:100-240Vac |
| VariationRange:90-264Vac |
| 2.2Input Frequency: |
| NominalFrequency:50/60Hz |
| VariationFrequency:47-63Hz |
| 2.3Input Current: |
| 1Arms max At any input voltage and rated, DC outputrated load. |
| 2.4Inrush Current: |
| 30Amps Max. Cold start at 240Vac input, with ratedload and 25℃ambient. |
| 2.5 Ac Leakage Current: |
| 0 |
| 3.OUTPUT CHARACTERISTICS: |
| 3.1Power Output; |
| Voltage Min.Load Max.Load Peak OutputPower |
| +12Vdc 0A 8A 8.6A 96W |
| 3.2 Combined Load/Line Regulation: |
| Voltage Min.Voltage Max.Voltage LineRegulation Load Regulation |
| +12Vdc 12.0V 12.6V ±5% ±5% |
| 3.3 Ripple And Noise: |
| The ripple andnoise are as follows when measure with Max. Bandwidth of 20MHz andParallel 47uF/0.1uF,crossed connected at testing point. |
| Voltage Ripple And Noise(Max.) |
| +12Vdc 100.5mVp-p |
| 3.4 Turn On Delay Time: |
| 2second Max. At 115Vac input and output Max. Load. |
| 3.5 Rise Time: |
| 40mSMax. At 115Vac input and output Max. Load. |
| 3.6 Hold Up Time: |
| 5mSMin. At 115Vac input and output Max. Load. |
| 3.7 Efficiency: |
| 80%Min.At 100Vac input and output Max. Load. |
| 83%Min.At 240Vac input and output Max. Load. |
| 3.8 Overshoot: |
| 15%Max.When power supply at turn on or turn off. |
| 3.9 No-load loss is not more than 1W . |
| 4.PROTECTION REQUIREMENT: |
| 4.1 Short CircuitProtection: |
| The power supply will be auto recovered when shortcircuit faults remove. |
| 4.2 Over current Protection) |
| Thepower supply will be auto recovered when over current faultsremove. |
| 4.3 Over Voltage Protection |
| The power supply will not be auto recovered whenfaults remove. |
| 5.ENVIRonMENTAL REQUIREMET: |
| 5.1 Operating Temperature: |
| 0℃to40℃,Fullload Normal operation. |
| 5.2 Storage Temperature:-20℃to85℃,Withpackage. |
| 5.3 Relative Humidity: |
| 5%(0℃)-90%(40℃)RH,72Hrs,Full load Normal operating. |
| 5.4 Vibration: |
| 1. Operating: IEC 721-3-3 3M3 |
| 5-9Hz,A=1.5mm (9-200Hz,Acceleration5m/s2) |
| 5-9Hz,A=3.5mm |
| 9-200Hz,Acceleration=5m/S2 |
| 200-500HZ,Acceleration=15m/S2 |
| 3.Axes,10 cycles per axis |
| No permanent damage may occur during testing. |
| The product has to restors itsoriginal situation after power off/on.) |
| 5.5 Dropping,Packed: |
| 1 corner,3 edges, and 6 surfaces |
| Height:76cm |
| 6.SAFETY AND EMC REQUIREMENT: |
| 6.1 Match standard with UL CE GS EK SAA ROHS |
| 6.2 DIELECTRIC STRENGTH(H-Pot): |
| (Primary tosecondary),3000Vac/5mA/60s. |
| 7.MECHANICAL REQUIREMENT: |
| 7.1 Enclosure: |
| The power supply size L:152*W:60*H:39mm |
| 7.2 (Input Connector) |
| 7.3;Output |
| DC cable: AWM 16AWG*2C,VW-1,80℃,FTI,300V,with word on the cord, Length:1.2M, withthe conector:5.5*2.5 |
| 8.Label |
| Material: PVC |
| Endure heat above110℃ |
| Thickness:0.2-0.3mm |
| 3*RI±0.1mm |
| 3*RI±0.1mm |
| Angle 2.5mm |
| 9 Packing |
| White inner box+outcarton |
| White inner box out side dimension |
| LxWxH(180x100x40) |
| Tolerance:±3 |