ITEM: Automatic Water Level Monitoring Equipment
Include one controller, one sensor, one alarm unit.
1. Technical parameter:
Power supply: 24V ± 10%
Quiescent current: < 200mA
Working current: 10A
2. Installation:
1) Preset the water upper limit level according to users' needs.
2) Install the controller according to user's requirement and be fastened with screws.
3) Plug the water level switch sensor into the controller's socket.
4) Connect motor wires of pump to the back terminals of controller(Two pumps(max) can be connected)[Note: Avoid inverse connection between anode and cathode]
5) Using power wire to make the both terminals of alarm unit and controller be well connected. (Note: Make sure there is no error connection between anode and cathode, or it will burn alarm unit out; Alarm unit which is built-in buzzer can give audible and visual alarm, and the sound can be turned off by user. )
6) Input DC 24V power to the controller through terminals following the direction and screw down. (Note: Make sure there is no error connection between anode and cathode, or it will burn controller unit out; )