Brand:Standardel
MOQ:1
Quantity:10
1. General
SDT670 DINrail power analyzer is designed special for energy managment system(EMS). By its DIN rail installation, it is very suitable to be usedwith breakers, contactors. Besides electrical energies, it maymeasure all the parameters on the electrical networks, such ascurrents, voltages, active powers, reactive powers, apparentpowers, frequency, power factors and 4 quadrantenergies.
It doesn''t needexternal CT, but we may connect it to up to 100Amp directly. It hasa 7 digits LCD display. By its front key and users may easilychange display data. Every SDT670 has a RS485 interface and 2impulse outputs, to transfer its measuring data to other masterdevices, such as PLC, data center computers.
SDT670 has good cost performance, as an intelligent unit anda digital electrical data collection unit, it has been widely usedin many intelligent systems.
2. Function
* Measuring 30 parameters on AC electricalnetwork:
AL1, AL2, AL3, VL1, VL2, VL3, VL1-2, VL2-3, VL3-1,Fr,
PL1, PL2, PL3, PL,QL1, QL2, QL2, QL, SL1, SL2, SL3, SL, PF1,PF2, PF3, PF,
imp & exp kWh, L & C kvarh
* With 7 digits LCD.
* Input: 3x5A (Connect CT), 3x20A, 3x32A, 3x100A,
* Line: 3P2L (2x110V/220V);
3P4L (3x120/220V, 3x220V/380V, 3x230V/400V);
3P3L (3x380V)
* The 3x5A type can be used with CT and CT ratio isprogrammable;
* With 2 impulse outputs (kWh, kvarh) and wire breakagealarm;
* With RS485 interfacer (Modbus-RTU protocol);
* 35mm standard DIN rail installation
* With StandardeL PC software, the user may easily read andSDT670 data and program its parameters by computer.With low powerand white LDC or 3 Red LED display, which may be well visible inany somber space.
3. Features
| Technical Feature | Parameters | |
| Input | Wiring | 2P3L, 3P3L, 3P4L |
| Voltage | 2x110V/220V, 3x120/220V, 3x220V/380V, 3x230V/400V, 3x380V | |
| Rating: 0.9 ~ 1.1Un; maximal: 0.7 ~ 1.2Un | ||
| Consumption ≤5VA / line | ||
| Current | 3x5A, 3x20A, 3x32A, 3x100A | |
| Minimal current 20mA | ||
| Minimal current 20mA | ||
| Consumption ≤4VA / line | ||
| Frequency | 50/ 60Hz | |
| Precision | 0.2%(U,I); 0.5% (F: 0.05Hz, kVarh: 1%) | |
| Thermal drift | <200ppm | |
| RS485interface | 2 cables RS485 (Modbus-RTU protocol) | |
| EnergyImpulse | 2 impulse (open-collector) for kWh &kvarh | |
| VCC<48V, Iz<50mA | ||
| Constant: 400~3200imp/kWh(/kvarh) | ||
| Width of pulse: 80ms±20ms | ||
| Installation | Standard 35mm DIN rail | |
| Standard | EN61036; EN50022 | |
| Isolation | 2kVAC/min ( input / output / power supply) | |
| input / housing and output / housing>50Mohm | ||
| Environment | Work Temperature: -20C ~ 55C | |
| Storage Temperature: -40C ~ 70C | ||
| Relative humidity: 5% ~ 95% (nocondensation) | ||
| Altitude: < 2500m | ||
| Dimension: 126×89×74 (mm) | ||
| Weight: 950g |