Metallurgy, Mineral & Energy
Thermal Gas Mass Flow Meter (GE-105)
2016-11-05 21:52  Views:195
Price:Negotiable
Send Inquiry

Features:
1. Apply high stability and patented technology platinum RTD sensor
2. Uses proprietary technology "balanced structure package", medium temperature self-compensation.
3. Proprietary algorithms; Can achieve high linearity, high repeatability, high precision.
4. Range ratio 1000: 1, also can be expanded according to user requirements.
5. Enables measurement of small flow large diameter, minimum flow rate can be measured as low as zero, resolution0.001m/s.
6. No moving parts, vibration can be neglected.
7. Straight pipe less demanding 1-2D.
8. Unrelated with the medium temperature and pressure.
9. Proprietary high-temperature method, medium temperature up to +510.
10. Humidity algorithm used to achieve high precision measurement.
11. Flow signal enter 12-point dynamic correction, built-in 10-point amendment.
12. Dynamic on-line correction current / voltage output.
13. Dont sensitive to dust and other small particles.
14. On-line continuous flow, easy handling and maintenance.

Structural forms: Integrated insert, pipeline
Performance:
* Measuring range: 0~120Nm/s (20C, 101.33Kpa)
* Accuracy: ± 1% of reading ± 0.5% full scale
* Range ratio: Usually 100: 1 (depending on the calibration of flow range)
* Diameter range: 10mm ~ 6000mm
* Application scope: Suitable for all types of single or mixed gases, containing dust, sand, moisture and various corrosive gases.
* Environmental temperature range: -40 ~ +85 (no display); -30 ~ +70 (showing); Humidity is less than 90% RH.
* Medium temperature range: -40 ~ +100; -40 ~ +200; -40 ~ +450; -40 ~ +510
* Sensor Diameter: 3, 2.5
* Plug-in sensor probe rod diameter: 19 (standard), 16, 12

* Sensor Material: 316 stainless steel, Hastelloy, Titanium
* Probe rod material (protection cover): 316 stainless steel (standard), Hastelloy
* Medium bi-directional flow measurement
* Analog Output: Flow: 4-20mADC, temperature: 4-20mADC, maximum load: 1000Ω
* Accumulated pulse output
* Type 12 non-linear correction, built-in 10 non-linear correction
* Communication: Serial output RS232/RS485

* Power supply: 24VDC/600mA; 220VAC/2W; 110VAC/3W
* Alarm: 1-2-way relay output, 5A/220V, 5A/30VDC, type settings
* Large-screen LCD Display: 7 instantaneous flow, 8 cumulative flow rate
* Process Pressure: 1.6Mpa (maximum 20MPa)
* Installation Process Type: Plug-in (card sets, card sets + ball valve, flange connection), pipeline type (flange, screw connection)
* Explosion-proof grade: Intrinsically safe (ia CT5), explosion-proof type (Exd CT4)
* Protection class: IP65.

Contact Infomation
Send Inquiry
Company name:A. Yite Group Limited
Status:[Offline] [Send message] [Chat]
Business contact:Smith Jack(Mr.)
Telphone:
Fax:
Area: Caribbean Region-Bermuda
Address:No. 46, Marble Rd, Hong Kong(China)