Handheld Pateint Monitor
2016-11-04 01:53  Views:114
Price:Negotiable
Send Inquiry

Parameters:
Five Parameters: ECG, NIBP, Pulse Rate, TEMP, SpO2.
Waveforms:
Two Waveforms: ECG waveform, SpO2 waveform (PLETH

Features:
1. Handheld; Compact, light, easy for carrying and handling.
2. Clear and bright LCD small screen real time display, Touch Screen.
3. Can be display the data and the waveform in a screen, and also can be switch between ECG waveform and PLETH.
4. English interface to simple read and handling.
5. Build-in rechargeable Ni/MH battery, longtime operating time.
6. Storage and review of patient trend data up to 36 hours which is never lost even when power is off.
7. Audio and visual alarm.
8. Battery capacity indicator.
9. Automatic power-off.

H. S. Code: 9018193000
Net Weight: 0.6kg
Gross Weight: 2kg
Package Size: 300x210x90mm

Standard accessories
1. One ECG cable with TEMP sensor
2. One NIBP cuff with extend tube
3. One SpO2 adult finger probe(soft)
4. One charger
5. One touch pen inside the model

Technical specification
ECG
Input: 3-core ECG cable, standard AAMI cable connector
Lead selection: I, II, III
Gain selection: X1, X2, X4, X8

Frequency response:
None filter: 0.05~100Hz (-3dB)
Filter: 0.5~40Hz (-3dB)
Scan Speed: 12.5, 25, 50 mm/S
ECG standard signal: 1mV square wave generated by hardware

Heart rate
Measure range: 20~250 bpm
Renew time: 1 time per beat
Accuracy: 1 bpm
Alarm limits range: Upper limits 80~250bpm, Lower limits 40~100 bpm
Alarm mode: Audible and visual alarm

NIBP
Measure Method: Automatic oscillometric
Average measure time: <40 seconds
Repeat Cycles: 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes

Alarm limits range:
SYS: Upper limits 120~250 mmHg, Lower limits 60~180 mmHg
DIA: Upper limits 80~150 mmHg, Lower limits 40~120 mmHg
MAP: Upper limits 100~230 mmHg, Lower limits 50~160 mmHg

SpO2
Measure Range: 35~100%
SpO2 Accuracy: 2%(70~99%), 3%(40~70%)
Pulse Rate Range: 0~254 bpm
Pulse Rate Accuracy: 1 bpm

Alarm limits range:
SpO2 upper limits: 95~99%
Lower limits: 85~96%
Pulse Rate: Keep up with the heart rate

Temperature
Input: Apply the same sensor with ECG
Measure range: 0~50ºC
Alarm limits range: Upper limits 36~45ºC Lower limits 34~38ºC
Measure accuracy: 0.1ºC

System specifications
Alarm ON/OFF: Controlled by general switch and parameter switch (two levels)
Display mode: Homochromy LCD hand touch screen
Waveform channel: Single channel
Trend data: 36-hour HR, SpO2, TEMP, SYS, DIA, trend data.
Dimensions: 114(D)X45(H)X150(W) mm