Brand:Chunlan
MOQ:50
Quantity:100
A,Scope
Air conditioner type:Cooling & heating room airconditioners
Refrigerant: R22
Rated Voltage/Frequency /Phase: 220-240V~ 50Hz 1φ
Ambient temp. range: -7°C~43°C
Evaporating temp. range: -5°C~15°C
Evaporating temp. range: 45°C~65°C
B,Rated performance parameter of compressor (at rated workingconditions)
Rated capacity : 3990W (13620BTU)
Input power: 1330W
Running current: 6.2A
EER: 3.0W/W
C,Rated working conditions
Evaporating temp.: 7.2°C
Suction gas temp.: 35.0°C
Condensing temp.: 54.4°C
Super-cooling temp.: 46.1°C
Ambient temp. : 35.0°C
D,Compressor date
Compressor type:Hermetic rotary refrigerant compressor
Displacement:: 23.5cm3
Oil brand : SUNISO 4GDID or ATMOS NM56EP
Oil charge: 445ml
Net weight:15.6Kg (Include oil)
Surface status: Black color paint
Suction tube (I.D) :φ12 mm
Discharge tube (I.D):φ10 mm
E,Motor date
Motor type: Permanent split capacitor
Pole:2
Rated output power:1090W
Locked current :31A
Maining winding:1.75±5%Ω(20ºC)
Starting winding:2.61±5%Ω(20ºC)
Insulation grade : Class B
F,Electrical component
1,Exterior overload protector:B235-145A-141A orB235-145-241A
2,Running capacitor (out of supply)
35μF/450V•AC
G,Specific performances
1,Noise:66dB(A) max
2,Vibration:30 m/s2 max
3,Motor winding temp.:130°C max
4,Leakage testing pressure
Higher pressure side: 2.9Mpa
Lower pressure side: 1.4Mpa
5,Mechanical strength pressure:
Higher pressure side: 10.5Mpa
Lower pressure side: 2.0Mpa
6,Insulation resistance(Filled with nitrogen gas): ≥30MΩ
7,Electric strength:AC 1500V 1min. (1800V 1sec)
8,Residual moisture:150mg max
9,Residual impurity:60mg max
H,Operating conditions
1. Start-up voltage:187V~264V
Running voltage:198V~264V
2,The period of the turning down and restarting the compressorshould be more than 3 minutes.
3,When the compressor has been installed into the refrigeratingsystem, it should be perpendicular to the leveling floor with maxinclination no more than 5°.
4,The residual moisture in the refrigerating system (not includecompressor) should not exceed 60ppm, the residual impurity in therefrigerating system (not include compressor) should not exceed20mg.
5,The filling amount of refrigerant should not exceed 1100g.
6,When the terminal cover is installed, the nut screw moment is1~1.5N•m.
7,The pipe and hermetic pens attached to the compressor shouldnot be bent..
8,The compressor should never be operated while under vacuum;otherwise, internal arcing can cause damaging parts.
9,The compressor should not be operated to form a vacuum and toadsorb air.
10,The compressor should not be left opend in the atmosphere formore than 15minutes.
11,The electric pulse should not be applied to the hermeticterminals when the compressor is under vacuum.
12,The compressor should be kept in the clean place withlow-moisture.
13,The compressor must not be applied for transportationequipment, such as automobiles, trains, ships, and others.
14,The compressor should not be splashed with waterintentionally.
15,Refrigerant should be charged from the end of condenser ofrefrigerating
systems. Never charge refrigerant to the compressordirectly.
16,Temperatures within systems during stable compressoroperation should not be less than -35°C to prevent waxprecipitation from the oil.
17,The lead wires should be connected to hermetic terminalswithout being touched on the surface of the compressor.
18,The compressor must be used according to the requirement ofthe specification.
Air conditioner compressor