Model:WDR0.06-0.7
Detailed introduction to (T Sun Brand) 45KW Vertical Automatic Electric Steam Generator Boiler:
1. FEATURES
The brand name is T-SUN, made in Shanghai.
98% thermal efficiency
Easy, quick to install
They require only a water feed connection and electrical hook-up
Applications include: steam for tanks, reactors, distillations, autoclaves, dyestuffs, food products, cosmetics, paraffins, glues, steam jacketed kettles, sterilizers, cosmetics, pipe tracing and humidification.
Built to China Boiler and Pressure Vessel CodesWater Feed System
Low Water Cut-off/Level Control automatically maintains proper water level, shutting off the boiler when water supply in the boiler drops below a safe operating level.
Water Level Sight Glass allows constant observation of water level while boiler is in operation.
Main On/Off Switch allows manual control of the boiler operating control circuit
Energy Savings and Minimum Maintenance
Pressure vessel insulation minimizes heat loss and maximizes energy savings, insured by fibrous glass material.
Operating Pressure Control resets automatically to maintain preset pressure within boiler.
Easy Control Maintenance
All control panels and components are easily accessible. Fully-louvered openings avoid component heat build-up.
Long Life Heating Elements
Industrial grade, heavy duty 0.420 inch diameter stainless steel heating elements equipped with one piece resistance welded terminations for added strength and safety.
The most important part, electric heating tube is designed by our retired nuclear industry engineer. The main material is nickel-chrome and magnesium powder of high quality so that the heat transfer is very efficient. We are the only electric boiler manufacturer who makes the electric heating tube by ourselves in China market.
2. SAFETY FEATURES
Real-time monitoring of water level: electronic water-level detecting device
Water shortage protection: The combustion control system power will be cut off when there is water shortage along with alarm.
Leakage protection: The power will be cut off when there is leakage detected by the control system.
Over pressure protection: When the pressure is over the preset value, the combustion control system power will be cut off along with alarm.
Steam Safety Valve automatically opens to reduce pressure should excessive steam cause pressure build-up.
Steam Pressure Gauge allows visual observation of steam pressure over full range.
Manual Reset Pressure Control provides high limit pressure cut-out with manual reset.
3. SPECS.
4. PICTURES