The Airsource 5601 DC Bench Top Ionizing Blower produces ionized air with balanced ion content. Ion offset voltage is continuously monitored and corrected through the combination of the unique emitter array design and control circuit. Ion balance is maintained with a high-gain dual feedback circuit. This circuit, combined with the units patented emitter array design, offers superior offset voltage performance. The unit is capable of maintaining +/-3V balance performance. If the unit becomes unable to track its set-point or some other atypical condition occurs, the built-in monitoring circuit indicates a fault.
Specification:
Operating Voltage | 110V/60Hz or 220V/50Hz |
Current consumption | 0.05A or 0.03A |
Operating Temperature | 0~50degrees |
Air Coverage | 40cm x 60cm |
Size | 90mm (L) x 170mm (W) x 200(H) |
Weight | 1.25Kg |
Air Volume | 50~100CFM |
Ion Balance | 0V±3V |
Decay Test Results :
Testing Conditions | ||||
Operating Voltage: 110V/220V Testing Voltage 1KV to 100V Temperature :22degrees | ||||
Distance |
| 300mm | 600mm | 900mm |
Decay time | Positive | 1.0s | 3.4s | 7s |
Negative | 0.9s | 3.5s | 8s | |
Offset voltage | Positive | 2V | 1V | 4V |
Negative | 2V | 1V | 3V | |