Send Inquiry
Features and use:
The product is equipped inside with reliable explosion-proof equipment and is highly safe. With its good self-healing characteristic and long life-span, it is widely used for air-conditioners, refrigerators, generators, illuminating lamps, etc.
Technical features: Climate types: 40/70/21
Capacity volume variance: ± 5%, ± 10%
Testing voltage: Between leading-out ends: 1.75UR, 10S no breakdown
Between leading-out end and shell: 2200VAC, 10S no breakdown
Insulation resistance: Between leading-out ends: ≥ 3000MΩ. µ F
Between leading-out end and shell: ≥ 1000MΩ
Loss tangent: Tgd≤ 0.002(50Hz)