Intelligent Pump Control Box, Model H522 is applied for automatic liquid level control / pressure control and effective protection for duoble pumps of with AC380V, 50hz, three phase output power 0.75 to 15kw (1hp-20hp), direct start, including stainless steel or cast iron

submersible pump, centrifugal pump, sewage pump etc.

Features:

1.Built In Function Switch To Apply Different Application

   Applied For Water Supply By Liquid Level Control

   Applied For Water Supply By Pressure Control

   Applied For Water Drainage By Liquid Level Control

2.Double Pumps Control 

   Main Pump / Standby Pump Automatically Alternate

   Main Pump / Standby Pump Automatically Switch Against Malfunctions

   Standby Pump Participate Running If Required

3.Computer Main Board And Module For Industrial & Civil Pump

4.Automatic Sops The Pump In The Case Of Water Shortage, Protecting It From Dry Running

   Without Installing Float Switch Or Liquid Probe In The Well

5.Auto / Manual Switch          

6.Pump Stalled Protection         

7.Transient Surge Protection

8.Over Current Protection        

9.Under Voltage Protection        

10.Light Alarm Signals Of Malfunction

11.Digital Voltmeter/Ampere Meter Real-Time Display

12.Push Button Calibration  

13.Starts And Stops The Pump In Accordance With The Different Liquid Level Or Pressure

     Setting

14.Present Liquid-Level Probe 

15.User-Friendly Connection Diagrams  

16.Integrated Design, Small Size, Easy To Install

Main Technical Specifications:

1.Rated Input Voltage:  AC220V Single Phase

2.Rated Frequency:  50Hz-60Hz (at option)

3.Rated Output Power of Motor: 0.37-2.2KW / 3-4KW

4.Dry Running Trip Response Time:  6sec

5.Over / Under Voltage Trip Response Time:  5sec

6.Pump Stalled Trip Response Time:  0.5sec

7.Over Current Trip Response Time:  5sec-5min

8.Recovery Time of Over / Under Voltage:  5min

9.Recovery Time of Over Current:  30min

10.Recovery Time of Dry Running:  30min

11.Over / Under Voltage Trip:  ±15%

12.Dry Running Trip:  70%

13.Pump Stalled Trip:  200%

 

Dimension:

276(L) x 125(W) x 370(H) mm

 