AC/DC metal Enclosed, 40W Single Output Switching Power Supply, S-40 Series.
Features:
1) Universal AC input
2) Short circuit, over load, over voltage protections
3) Cooling by free air convection
4) 100% full load burn-in test
5) Fixed switching frequency at 36 KHz
6) 30 pcs / per cartoon box
Specifications:
Input Voltage: 85 ~ 264Vac 120V ~ 370Vdc
Input Frequency: 47 ~ 63Hz
Input Current: 1.2A/115Vac 0.6A/230Vac
Inrush Current: 25A/115Vac 50A/230Vac, Cold start
Leakage Current: <1mA/240Vac
Set Up, Rise Time: 300ms, 50ms/230Vac 800ms, 50ms/115Vac at full load
Hold Time: 70ms/230Vac 15ms/115Vac at full load
Over Load Protection: 105%~150% rated output power
Hiccup mode, recovers automatically after fault condition is removed
Over Voltage Protection: Hiccup mode, recovers automatically after fault condition is removed
Working Temperature: -10°C to +60°C (Refer to output load derating curve)
Working Humidity: 20 ~ 90% RH non-condensing
Storage Temperature, Humidity: -20°C to +85°C, 10 ~ 95% RH
Temperature Coefficient: ±0.03%/°C (0 ~ 50°C)
Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X,Y, Z axes
Withstand Voltage: I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Safety Standards: UL 1012, UL60950-1, TUV EN60950-1 Approved
EMC Standards: Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3, ENV50204,
EN61000-4-2,3,4,5; EN55024, Light industry level, criteria A
MTBF: 314.1K hrs min. MIL-HDBK-217F (25°C)