1. Gereral º C
Main supply AC 100V± 5%(50Hz/60Hz)
Rating 0--30V, 0--1.5A
Dimension 225mm*95mm*150mm (l*b*h)
Weight 4.5kg
Operating Time 8 hours
Protection current limit
Power consumption 110VA
Operation Environment Indoor use: None
Operation Temperature & Humidity 0--40º CStorage Temperature & Humidity -20º C--135º CAccessories Power cable
2. Constant Voltage Operation
(1)Output voltage ranges 0 to rating voltage continuously adjustage: None
(2)Voltage regulation
Line regulation(± 10%) ??5*0.01%+1mV
Load regulation(output current 0--100%) ??5*0.01%+3mV
(3)Recover time(50% Load change, minimum load 0.5A) <200ms
(4)Ripple & Noise ??1mVrms
3. Constant Current Operation
(1)Output current ranges 0 to rating current continuously adjustage. None
(2)Current regulation
Line regulation(± 10%) ??0.2%+2mA
Load regulation(output current 0--100%) ??0.2%+3mA
(3)Ripple & Noise ??3mArms
4. Indicator Meter
Display
Voltage 3 1/2 digital meters
Current
Resolution
Voltage 0.1V
Current 10mA
Accuracy
Voltage ± 1%+2dgts
Current ± 2%+2dgts
Range
Voltage 0--99.9V
Current 0--99.9A
5 Insulation
Between chassis and output terminal 500V
Between chassis and AC cord. 1500V
6. Packing
Inner carton with buffer protecting 1pce
Outer carton 4pcs
7. Business term
Export Port FOB Shanghai
MOQ 2 00pcs
Price Depending on the yearly forecast
Term of Warranty Within 1 year after shipment
Lead time 45 days
Payment T/T 30days