Railway Cable
Railway Signal Cable
Railway Data Signal Cable
Inner Shielded Railway Data Signal Cable Through-Railway Ground Wire
Aluminium sheath, Comprehensive sheath Axle counter cables Low Smoke Halogen Free Flame Retardant Railway Control Cable
Railway Long Distance Symmetric Cable
Usage
500V1000V, , .
It is used in rated voltage up to AC 500V or DC 1000V control circuit as railway signal transmission and communication, audio signal or automatism signal, the multi-sheath railway signal cable has screen character, which is suitable for laying in electrified railways or others field under strong Interference.
Operating Characteristics:
1.1 -40C~+60C.
1.2 +70C.
1.3: 0C; -20C.
1.4: 10; 15.
1.5 ≤ 0.8; ≤ 0.3
1.1 The ambient temperature: -40 deg. ~+60 deg.
1.2 the operating temperature should not be higher than +70deg.
1.3 The ambient temperature under installation, PVC sheath cable should not be below 0 deg., PE sheath cable should not be below -20 deg.
1.4 mini bending radius: Non-armoured cable>=10 times of the cable diameter armoured cable>=12 times of the cable diameter
1.5 multi-sheath train signal cable screening factors ≤ 0.8 aluminium sheath train signal cable screening factors ≤ 0.3
Types and Description
TYPES
Name
Installation Scope()
Specification (core)
PTYV
PE insulation, PVC sheath, railway signal cable
For laying in tunnel, cable trench, or direct in ground, able to bear certain external mechanical forces
4689 12141619212428303337424448525661
PTYY
PE Insulation, PE sheath railway signal cable
PTY22
PE insualtion, steel tape armour, PVC outer-sheath railway signal cable
For laying in tunnel, cable trench, or direct in ground, able to bear larger external mechanical forces
PTY23
PE insulation steel tape armour PE outer-sheath railway signal cable
PTYA22
PE insulation comprehensive sheath steel tape armour PVC outer-sheath railway signal cable
PTYA23
PE insulation comprehensive sheath steel tape armour PE outer-sheath railway signal cable
PTYL22
PE insulation, Aluminium sheath, steel tape armour, PVC outer-sheath railway signal cable
PTYL23
PE insulation, aluminium sheath, steel tape armour, PE outer-sheath railway signal cable
Types Code Instruction
Code
Instruction
Code
Instruction
PT
Railway Signal Cable
22
Double Steel Tape Armour PVC Outer-sheath
SPT
Railway digital signaling cable
23
Double Steel Tape Armour PE Outer-sheath
YW --
Physically foamed skin-foam-skin polyolefin insultaion
03
Non-armour PE Outer-sheath
Y
Polyolefin insultaion or Sheath
H
Cold Resistant
P ()
Inner Shield (Digital Cable)
DWZR
Low somke halogen free &flame retardant
P ()
Copper wire braided screen (Data transmission cable for balise)
-FBY
Termite resistant type
L
Aluminium Sheath
-GP
High-performance shielding type
A
Comprehensive Sheath
PJ
Axle Counter Signaling Cable
HE
Long distance symmetric cable
LEU. BS
Data transmission cable for balise