Send Inquiry
1. Demoulding method:
Horizontal mould-opening + vacuum suction
2. Mould Matching Method:
By hydraulic pressure
3. Pressure of mould matched: 310, 000 N
4. Precision of mould match: ± 0.25mm
5. Low-pressure of slip feeding: 0.02~0.05MPa
6. Hi-pressure of slip feeding: 0.8~1.0MPa
7. Pressure increased method of slip: By Hydraulic Pressure Machine.
8. Pressure of compressed air: ≥ 0.6MPa
9. Pressure of water: 0.3MPa
10. Quantity of mould: 8sets
11. Total forming cycle: 16~20minutes/cycle
12. Total Power: 12.05kW
13. base taking method: By manual
14. Overall dimension: L× W× H 8800× 2600× 2700mm.