Integrative temperature transfer.
A. Summarize
SBWR series thermocouple temperature transfer and SBWZ series thermal resistance are the temperature unit on the spot installation, belong to the DDZ-s series meters. It adopt the two line transfer (the power input and signal output are two conductor), output and tested temperature pro rata linearity 4~20mA current signal. The transfer can install in the thermocouple or thermal resistance. As the new meters, it can used in the scientific research, metallurgy, petroleum, chemical industry, textile, plastic, food, energy-saving fields and so on for the temperature test automatically, transfer and control.
B. Technical parameter
1. Basal error: ±0.2%, ±0.5%;
2. The effect by the surrounding temperature change: 0.2 0.02%FS/º C;
0.5 0.05%FS/º C;
3. Output signal: 4~20mA,
4. Load resistance: 0~600??
5. Power: 14~34VDC;
6. Work condition: (1) Surrounding temperature: -25 ~ +85º C or-30 ~ +120º C
(2) Relatively temperature: 5~95%RH, No condensation
7. Protection: Safety ia IIC.