UV BALLAST for T4, T5, T8
Input
1. Constant current source, sine wave
2. Input voltage 100-240V for American market or 230V AC for international markets
3. Input factor 0.99 Output
4. Preheat start functionality or instant start
5. Number of lamp -1 OPERATING VERTICALLY
6. Lamp power from 80W -200W, according to you lamp test, make sure meet you need!
7. Lamp type-low pressure high output mercury vapor UV germicidal lamp
8. High frequency: 55.5kHz
9. Maximum ballast power: 200W
10. Maximum available starting voltage: 800V RMS
11. Ballast efficiency: >85%
12. Steady state current: Up to 1200MA(200W)-other currents over 800MA maybe
13. Ballast will attempt to ignite lamp once and then require power reset to strike again
14. Ignition duration-100ms(min)
15. Output protection-against end of lamp life; Against lamp not connected; Against short circuited lamp; Against lamp overvoltage
16. "lamp on" indication-optional(for example to power an LED)
17. "lamp on" dry contact-optional (for example to power a valve)
Environmental
18. Ambient Temperature: 0-55 celsuis degree
19. Relative humidity 10%-90%
20. Ballast will have no forced air cooling-just convection
21. Mounted vertically within plastic enclosure.