Send Inquiry
One Si-Capacitive Cell, integrated into microelectronic circuit
Adjustable characteristic via electronic calibration
Pressure range: 0, 1 to 1 bar (MAP, BAP)
0, 2 to 3 bar (Turbo MAP)
Temperature range: -40 to 125C (Storage: 135C)
Supply voltage: 5 V 0.5 V
Transfer function: Linear to applied pressure, ratiometric, adjustable
Accuracy over full-scale: 1 % full span (10 to 85 C)
Response time: <1 ms (10...90%)
Power on time: <10 ms
Option: Integrated Temperature Sensor (NTC)