Model:FVCM
Send Inquiry
Vacuum spray cooling water tank for PE pipe extrusion line
—Vacuum calibrating water tank is mainly used to achieve vacuum calibrating and cooling.
—Water level and temperature automatically control.
—Length: 6000 mm.
—Tank material: stainless steel, 5 mm thickness.
—water supply way: concentrated water supply, 4 direction spraying.
—Vacuum pump motor type, power: SIEMENS brand, direct link seal vacuum pump, 5.5kw (2 sets).
—Vacuum degree (MPa): 0~0.09MPa.
—Water pump power: Siemens brand, water pump: 5.5kw, 2 sets.
—Moving motor power:1.1kw.
Technical list :
| Technical Desricption | VT63X6m | VT63X9m | VT110X9m | VT160X6m | VT160X9m | VT250X9m | VT400X9m | VT630X9m | VT800X9m |
| Working Range (mm) | Ø 16-63 | Ø 16-63 | Ø 20-110 | Ø 20-160 | Ø 90-250 | Ø 160-250 | Ø 160-400 | Ø 250-630 | Ø 400-800 |
| Tottal Length(m) | 6 | 9 | 9 | 6 | 9 | 9 | 9 | 9 | |
| Chambers | SINGLE | DOUBLE | DOUBLE | SINGLE | DOUBLE | DOUBLE | DOUBLE | DOUBLE | DOUBLE |
| Vacuum Pumps (kW) | 4 | 3 + 3 | 3 + 4 | 5.5 | 3 + 4 | 4 + 5.5 | 4 + 5.5 | 5.5 + 7.5 | 5.5 + 7.5 |
| Water Pumps (kW) | 4 | 3 + 4 | 3 + 4 | 4 | 4 + 5.5 | 7.5 + 7.5 | 7.5 + 7.5 | 7.5 + 11 | 7.5 + 11 |
| Nozzles (pcs) | 98 | 178 | 208 | 178 | 268 | 288 | 320 | 388 | 436 |
| Moving Distance (mm) | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| Motion Motor (kW) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 | 1 | 1 | 1 |
The photo of PE Pipe Vacuum Spray Cooling Tank