Metallurgy, Mineral & Energy
Pure Sine Wave Inverter (1KVA~30KVA) (SME-PIV60)
2016-10-25 15:52  Views:300
Price:Negotiable
Send Inquiry

Ideal Application

Telecommunications

End User equipment sensitive to the power supply interferences

All critical environment which needs stable, reliable and uninterruptible true sine wave power supply

Features & Benefits

SPWM technology, true sine wave output.
Advanced anti-jamming technology, highly efficient filter, good electromagnetism compatibility, compatible with all kinds of communication equipment.
Good adaptability of RC and RL loads.
Automatic bypass. Transfer time is less than 8ms when failure. It allows supplying power to the load without interruption.
LCD displays the operating status of inveter, load and battery capacity etc.
Monitoring software offers several different communication and connection options(RS232 and SNMP) to manage your inveter.
Modular design allows for quick repair and easy field upgradeability.
Extra low noise and good overload capability Applications Telecommunications.
End user equipment sensitive to the power supply interferences.
All critical environment which needs stable, reliable and uninterruptible true sine wave power supply.

Technical Specifications

Model
48V for telecom
110V for railway
220V for electric power

S1KVA-3KVA
D4KVA-D20KVA
E1KVA-E30KVA

Capacity
1KVA-3KVA
4KVA-20KVA
1KVA-30KVA

DC Input

Voltage Rating
48V
110V
220V

Votlage Range
40~57V
92~131V
184~261V

Ripple
<40mV
<40mV
<40mV

AC Input

Phase
Single Phase + GND

Voltage
220V± 20%

Frequency
50Hz± 5%

AC Output

Voltage
220V± 1%

Frequency
50Hz± 1%

Waveform
True Sine Wave

THD
<3%(Linear Load)

Transmission Interference Limit
0.15~0.5MHz, Peak Value<79dB, Average<66dB

0.15~30MHz, Peak Value<73dB, Average<60dB

Efficiency
>80%

Overload capability
When Load Current Is Greater Than 120% Rated One, Inverter Automatically Transfers to Bypass After 20s,

And Then Automatically Recovers or Restarts.

Transfer Time
0ms

Noise
<55dB

Protection

DC Input
Low DC Shut Down

Over Temp
When Internal Temperature >85, Automatically Transfers to Bypass

Short Circuit
Current Limitation, Fuse and Breaker Protection

Fault
Automatically Transfer to Bypass

Alarm

Bypass Failure
Beep Every 4S, Silent After 30s

DC Low
Beep Every 1s

Overload
Overload Indicator Flashs, Long Beep

Fault
Fault Indicator On, Long Beep

LCD/LED

LCD
Display AC Input/Output Voltages, Frequency, DC, Input/Output Wattages

LED
Utility, Normal, Overload, DC Low, Fault

Interface
RS232/SNMP

Environment

Temperature
0~40

Humidity
20%~90%(Non-comdensing)

Insulation Resistance
EN50081, EN55022

HI POT
EN50081, EN55022

Contact Infomation
Send Inquiry
Company name:China SME Group Co., Limited
Status:[Offline] [Send message] [Chat]
Business contact:Wong Tony(Mr.)
Telphone:
Mobile:
Fax:
Area: Caribbean Region-Bermuda
Address:Room 603, Engel Plaza. No. 287, Songhuajiang Road, Shanghai, China